Shuaa Al Zahra is one of the leading company of fire safety equipment in Saudi Arabia. Our company deals with a multitude of fire extinguishers and fire protection products like Fire Suppression System, Water mist & Specialised Products, etc. and now we are anticipating into Fire Extinguisher Refilling Services.

Your extinguisher must undergo routine checks and maintenance in order to ensure perfect functionality. Understanding this is instrumental when it comes to effectively controlling and extinguishing fires in your home or property in KSA.

How Do Extinguishers Work?

A fire extinguisher consists of a large aerosol can typically containing two substances: a solid, gas, or liquid substance, and a propellant. Propellants are pressurized chemicals that eject fire-fighting substances from their cylinders when the handle is pressed.

There are four major extinguishers, and using the right extinguisher at the right time is as essential as understanding how extinguishers work. Addressing a fire with the wrong extinguisher may cause more harm than good.

  • Water Extinguishers: These extinguishers are water-filled tanks using carbon dioxide or nitrogen as propellants. Water extinguishers are the most widely used type of extinguisher, helping eliminate heat from fire while cutting off the supply of oxygen.
  • Foam Extinguishers: These are foam-filled extinguisher tanks using nitrogen as their propellants. Foam extinguishers work by smothering the fire, absorbing its heat. When used, the foam spreads thinly over the fire, cutting oxygen supply and containing the heat. Its heat-absorbing property is aided the water the foams contains.
  • Dry Powder Extinguishers: These extinguishers contain dry powder, using nitrogen as their propellants. In this use case, dry powders help absorb heat, then melt and coat the fuel, consequently cutting off the oxygen supply and containing the fire. Dry powder is typically a mixture of chemicals, including mono-ammonium phosphate, potassium bicarbonate, sodium bicarbonate, etc.
  • Carbon Dioxide Extinguishers: CO2 extinguishers have gaseous and liquid carbon dioxide in their tanks, stored under high pressure to liquify it even further. When released, the gas expands, smothering oxygen and absorbing surrounding heat when it turns from a liquid into a gas (the latent heat of vaporization).

How To Maintain Fire Extinguishers

A failing extinguisher can have devastating consequences. Therefore, you must routinely inspect and maintain its cylinder to keep it in a perfect working state. Below are a few practices to follow in order to properly maintain your cylinder:

Conduct Monthly Visual Inspection of Your Extinguishers

  • Visually inspecting your extinguishers monthly helps you:
  • Ensure easy accessibility of the extinguishers
  • Confirm damages, such as cracks, rusts, or dents on the cylinder
  • Ensure the proper placement of the pin and tamper seal
  • Confirm any damages or aging of hose and nozzles (if available)
  • Confirm the gauge’s needle points to the green portion of the dial, etc.

If any of these aren’t as they should be, contact a professional and licensed fire extinguisher maintenance company for possible fixes.

Service All Extinguishers in 06 Months

Apart from the monthly visual checks, ensure you service your extinguishers within 06 months – allow our experts at Shuaa Al Zahra Safety Company to handle the process for you. After servicing, ensure each extinguisher has a tag showing the last inspection and service date for proper referencing. You may need to repair or replace any extinguisher as recommended by the maintenance company used.

When To Refill Your Fire Extinguisher Cylinder

Refilling your cylinder is an important apart of fire extinguisher maintenance, ensuring the device is always available to work when you need it most. However, understanding the importance of refilling is entirely different from knowing when a refill is needed. Here are several reasons to refill your extinguishers:

You must refill fire extinguishers immediately after each use.

You must schedule routine refilling of extinguishers throughout their lifespan, regardless of if they have been used or unused. Such refilling typically takes place every six to twelve years from the manufacture date.

Damages, dents, and other environmental factors may result in depressurizations. Hence, you must examine and refill your extinguishers whenever any of these is detected.

How To Refill Your Fire Extinguisher Cylinder

Having understood when to refill your cylinder, it is just as important to learn the ways to refill your cylinder when the need arises.

We at Shuaa Al Zahra Safety Company, have the required training, knowledge, and tools to help you achieve this.

  • Keep in mind that the steps below are a general overview of what to expect in order to help you better understand the process of refilling, rather than a detailed guide on the step by step process.
  • First, completely depressurize the extinguisher. Remove the agent from the cylinder.
  • Next, remove the discharge valve from the cylinder.
  • Remove the siphon tube, valve stem, and sprig from the valve.
  • Clean the valve and replace the valve neck while inspecting externally and internally for possible damages.
  • Reassemble the valve. Ensure the new valve stem is included in the reassembling to ensure proper seating while avoiding future loss of pressure.
  • Refill the empty cylinder with the extinguishing agent, whether dry powder, water, or carbon dioxide. Ensure that the refilled content conforms to the recharging instructions in the cylinder specification manual, and is appropriate for the unit’s size.
  • Repressurize the unit with the right pressurizing gas to the required pressure, as noted in the recharging instructions in the cylinder specification manual.
  • Conduct a Leak Test (usually conducted by a trained technician) to rule out any signs of leakage.
  • Reinstall the discharge hose or nozzle.
  • Reweigh the extinguisher to ensure its total weight doesn’t exceed allowable tolerances as specified by the manufacturer.

Understanding how to maintain and refill your fire extinguisher is essential to keeping your home or commercial property safe from fire damage. Reach out to our experts with any questions you may have when it comes to ensuring your fire safety.

Fire Extinguisher Refilling Process

The process of refilling fire extinguishers at Vibrill Firesafe Private Limited typically involves the following steps:

Inspect Fire Extinguisher

1. Inspection: The first step the technician does is visually inspect the fire extinguisher to ensure that it is in good condition and does not have any visible damage or leaks. The technician will also check the pressure gauge to ensure that the pressure inside the extinguisher is within the recommended range.

Discharge Fire Extinguisher

2. Discharge: Next, the technician will discharge the remaining contents of the fire extinguisher by pressing down on the handle until all the extinguishing agent has been expelled. This is typically done in a designated area or a special machine designed to capture the expelled agent.

Dismantling Fire Extinguisher

3. Dismantling: Once the extinguisher has been discharged, the technician will dismantle it to access the internal parts. This involves unscrewing the head, separating the internal components, and cleaning them thoroughly.

Refilling Fire Extinguisher

4. Refilling: The next step is to refill the extinguisher with the appropriate type and amount of extinguishing agent. The technician will carefully measure and pour the agent into the extinguisher, taking care not to overfill it.

Reassemble Fire Extinguisher

5. Reassembly: After refilling the extinguisher, the technician will reassemble all the internal components, replace the head, and ensure that all the seals and fittings are secure and tight.

Pressure testing of fire extinguisher

6. Pressure Testing: Once reassembled, the technician will pressurize the extinguisher to the recommended pressure level using a special machine or gauge. This ensures that the extinguisher is ready to use and can deliver the correct amount of agent when needed.

Quality checking of fire extinguisher

7. Quality Check: Finally, the technician will perform a quality check to ensure that the extinguisher is functioning properly and meets all safety standards. This includes checking the pressure gauge, testing the discharge mechanism, and inspecting the exterior of the extinguisher for any damage or defects.

Measuring the weight of the extinguisher

8. Weighting : Fire extinguishers are an important part of fire safety. Refilling them can be a hassle and often leaves customers unsure if they’re getting the right amount of agent. That’s why we’ve developed a revolutionary new refilling process that includes a final step of measuring the weight of the extinguisher.

***************************************************

Pls send us all your enquiries / help / support/ Annual Maintenance Contract (AMC) at Email:

Sales@shuaa-alzahrasafety.com

WHY REFILLING OF FIRE EXTINGUISHERS?

Refilling of fire extinguishers are used to make sure your extinguishers are prepared to handle a fire emergency at any given time. If you fail to schedule regular inspections to recharge your extinguishers, you increase your chances for equipment malfunction and Shuaa Safety wants to give special attention to it across the Kingdom of Saudi Arabia.

WHEN IS REFILLING OF FIRE EXTINGUISHERS IS REQUIRED?

Fire extinguishers need to be recharged immediately after each use

If the extinguishing agent inside was not completely discharged, the extinguisher still needs to be serviced in order to make sure it’s ready for its next use

Fire extinguishers need to be recharged periodically throughout their life

The statutory framework in the country makes it mandatory to refill your fire extinguisher

WHY SHUAA AL ZAHRA’S REFILLING SERVICES?

Best in class facilities and the certified refilling stations

Partnered with highly skilled and trained professionals from the industry

100% customer satisfaction

Guaranteed on-time delivery

OUR MAINTENANCE SERVICES INCLUDES:

FIRE PUMP SYSTEM

FIRE DOORS

PORTABLE FIRE EXTINGUISHERS

AUTOMATIC FIRE EXTINGUISHERS

MOBILE FIRE EXTINGUISHERS

FIRE HOSE REELS

FIRE HOSE RACKS

FIRE CABINETS

FOAM SYSTEMS

HYDRANT SYSTEMS SPRINKLER SYSTEMS

CO2 EXTINGUISHING SYSTEMS

CO2 EXTINGUISHING SYSTEMS

FK5112 EXTINGUISHING SYSTEM

KITCHEN HOOD SYSTEM

THERMO-ACT SYSTEM